I don’t remember if they fully closed the loopholes, but there are inputs that programs cannot catch unless you actually replace the OS.
I don’t remember if they fully closed the loopholes, but there are inputs that programs cannot catch unless you actually replace the OS.
You don’t normally need to specify that the sides are parallel if you specify four right angles.
Here in NZ they do a factory reset on your calculator at the start of every exam.
When you download a torrent, you’re downloading it from someone else’s computer. That ‘someone else’ is usually an individual, not some file sharing site with redundant servers.
When you download a torrent, someone had to send it. It’s a small cost for individual torrents, but they had to pay for energy, internet connection, hard drives etc. If more people seed the torrent, you get a small bit of it from each seed, spreading the burden.
If no-one with the torrent has their computer on and seeding it, you cannot download the file, because there is no-one to download it from. If there are several seeds with the torrent, then you can still download it even if one or more seeds turn the computer off at night, delete the file, or are overloaded.
Even 95% is on the low side. Most residential-grade PV grid-tie inverters are listed as something like 97.5%. Higher voltage versions tend to do better.
Yeah, filters essentially store power during one part of the cycle and release it during another. Net power lost is fairly minimal, though not zero. DC needs filtering too: all those switchmode power supplies are very choppy.
Well, that’s certainly the answer.
I wouldn’t have thought you’d want to put a building quite that close to the waterfront even in a Fjord, but apparently they did.
I don’t think the US/Canada usually does that style of power pole, with three phases on a crossarm and no neutral below.
Barriers on what looks like a pretty low-traffic low-risk road too.
I would think somewhere Scandinavia or central Europe. NZ wouldn’t put barriers like that up.
Rock wall near bottom of picture screams old.
I’m not sure there are any power grids past the tens-of-megawatt range that aren’t just a 2/3/4 terminal HVDC link.
Railway DC supplies usually just have fat rectifiers and transformers from the AC mains to supply fault current/clearing and stability.
Ships are where I would expect to start seeing them arrive, or aircraft.
Almost all land-based standalone DC networks (again, not few-terminal HVDC links) are heavily battery backed and run at battery voltage - that’s not practical once you leave one property.
I’m sure there are some pretty detailed reports and simulations, though. A reduction in cost of multi-kV converters and DC circuit breakers is essential.
PV inverters often have around 1-2% losses. This is not very significant. You also need to convert the voltage anyway because PV output voltage varies with light level.
Buck/boost converters work by converting the DC current to (messy) AC, then back to DC. If you want an isolating converter (necessary for most applications for safety reasons) that converter needs to handle the full power. If it’s non isolating, then it’s proportional to the voltage step.
Frequency provides a somewhat convenient method for all parties to know whether the grid is over- or under- supplied on a sub-second basis. Operating solely on voltage is more prone to oscillation and requires compensation for voltage drop, plus the information is typically lost at buck/boost sites. A DC grid would likely require much more robust and faster real-time comms.
The AC grid relies on significant (>10x overcurrent) short-term (<5s) overload capability. Inrush and motor starting requires small/short overloads (though still significant). Faults are detected and cleared primarily through the excess current drawn. Fuses/breakers in series will all see the same current from the same fault, but we want only the device closest to the fault to operate to minimise disruption. That’s achieved (called discrimination, coordination, or selectivity) by having each device take progressively more time to trip on a fault of a given size, and progressively higher fault current so that the devices upstream still rapidly detect a fault.
RCDs/GFCIs don’t coordinate well because there isn’t enough room between the smallest fault required to be detected and the maximum disconnection time to fit increasingly less sensitive devices.
Generators are perfectly able to provide this extra fault current through short term temperature rise and inertia. Inverters cannot provide 5-fold overcurrent without being significantly oversized. We even install synchronous condensers (a generator without any actual energy source) in areas far from actual generators to provide local inertia.
AC arcs inherently self-extinguish in most cases. DC arcs do not.
This means that breakers and expulsion type fuses have to be significantly, significantly larger and more expensive. It also means more protection is needed against arcs caused by poor connection, cable clashes, and insulation damage.
Solid state breakers alleviate this somewhat, but it’s going to take 20+ years to improve cost, size, and power loss to acceptable levels.
I expect that any ‘next generation’ system is likely to demand a step increase in safety, not merely matching the existing performance. I suspect that’s going to require a 100% coverage fibre comms network parallel to the power conductors, and in accessible areas possibly fully screened cable and isolated supply.
EVs and PV arrays get away with DC networks because they’re willing to shut down the whole system in the event of a fault. You don’t want a whole neighborhood to go dark because your neighbour’s cat gnawed on a laptop charger.
There should be no need for tuning, tweaking, or optimizing on functionality this basic.
If you ask the processor, it will spit out a graph like this telling you what threads/cores share resources, all the way up to (on large or server platforms) some RAM or PCIe slots being closer to certain groups of cores.
Acorn/ARM apparently did much the same thing.
More generally, -ate itself means ‘with oxygen’.
Carbonate = carbon + oxygen
Nitrate = nitrogen + oxygen
Phosphate = phosphorus + oxygen
There is apparently some nuance but it is a good rule to remember: https://chemistry.stackexchange.com/questions/32962/when-to-use-ate-and-ite-for-naming-oxyanions
It was a few years back, but after it hit ChromeOS EOL I’m pretty sure it just got some KDE distro; I don’t think I even used LXDE. Didn’t need to do much.
I was mostly using it for web browsing, forums, spreadsheets, documentation etc. Nothing particularly strenuous.
I did have one really fun time of modifying PDF engineering drawings by opening them in Libre Office Draw which it handled kinda OK.
It did get a 240GB SSD but everything else was soldered.
I got a surprising amount of use out of a similarly configured C720 as a general purpose portable machine.
Essentially no processors follow a standard. There are some that have become a de facto standard and had both backwards compatibility and clones produced like x86. But it is certainly not an open standard, and many lawsuits have been filed to limit the ability of other companies to produce compatible replacement chips.
RISC-V is an attempt to make an open instruction set that any manufacturer can make a compatible chip for, and any software developer can code for.
I’ve certainly never heard of a chicken ranch, but plenty of chicken farms.
Only 15mL and into a syringe, right?
Yeah, I have no idea either, but it’s been around for more than a decade so it should be fairly easy to find a library that duplicates it.
I would be wary of AI-based solutions. There’s a risk of it picking up e.g. satirical/spoof sponsorships as actual ads, and perhaps not detecting unusual ads.
I’m slightly terrified of the day someone starts getting AI to reword and read out individual ads for each stream.
Indeed, the US has a major lack of fixed-line competition and lack of regulation. Starlink doesn’t really help with that, at least in urban areas.
I’m not familiar with the wireless situation. You’re saying that there are significant coverage discrepancies to the point where many if not most consumers are choosing a carrier based on coverage, not pricing/plans? There’s always areas with unequal coverage but I didn’t think they were that common.
Here in NZ, the state funding for very rural 4G broadband (Rural Broadband Initiative 2 / RBI-2) went to the Rural Connectivity Group, setting up sites used and owned equally by all three providers, to reduce costs where capacity isn’t the constraint.
Any hard drive can fail at any time with or without warning. Worrying too much about individual drive families’ reliability isn’t worth it if you’re dealing with few drives. Worry instead about backups and recovery plans in case it does happen.
Bigger drives have significantly lower power usage per TB, and cost per TB is lowest around 12-16TB. Bigger drives also lets you fit more storage in a given box. Drives 12TB and up are all currently helium filled which run significantly cooler.
Two preferred options in the data hoarder communities are shucking (external drives are cheaper than internal, so remove the case) and buying refurb or grey market drives from vendors like Server Supply or Water Panther. In both cases, the savings are usually big enough that you can simply buy an extra drive to make up for any loss of warranty.
Under US$15/TB is typically a ‘good’ price.
For media serving and deep storage, HDDs are still fine and cheap. For general file storage, consider SSDs to improve IOPS.