along these lines, you should also know about the condensate drain from your air conditioner – since water drips out of it all summer, it has a tendency to grow some algae or mold, and if it plugs up your air conditioner may flood and ruin your ceiling/walls/floor.
it’s worth paying that AC guy to come by every couple of years even if you’re not on their service plan.
for what it’s worth, coolant is not consumed by an air conditioner – the same initial charge can last 20+ years. Low coolant either means a leak, which the technician should have investigated and fixed or ruled out, or improper initial installation.
Betavoltaics have been around for 40+ years. https://en.m.wikipedia.org/wiki/Betavoltaic_device
This device generates microwatts. You’d need thousands of them in parallel to power a typical mobile phone.
All of their tech job openings are in India or Vietnam. I’d have assumed a major US health data handler would be developing onshore!
Surge suppressors do not drop extra voltage to ground. They selectively short out surges between whatever two conductors have a high potential between them.